Logo Logo
  • Home
    • Home
    • Editorial Board
    • Goal of the Journal
    • Submission of Papers
    • License Agreement
    • Open Access Statement
    • Guidelines for Authors
    • Peer Review Process
    • Archiving and Deposit Policies
    • Ethics of the Journal
    • Browse Journal Archive
  • Browse journal archive
  • Home
  • Archive: 2011
05 Feb 2011
  • 2011
  • V. 10
  • 1
  • (p.121 - 130)

Optimization study of a transportable neutron radiography system based on a 252CF neutron source

Authors:

Fantidis, J.; Potolias, C.; Vordos, N.; Bandekas, D.

Summary:

The purpose of this work is the optimization of a transportable thermal neutron radiography system. Neutrons are produced by a 50 mg 252Cf source. The design was optimized with respect to parameters related with thermal neutron radiography and shielding. Owning to the special collimator design, it was possible to optimize the neutron radiography parameters, while the use of advanced shielding materials reduced the weight and the volume of the unit. The unit was compatible with the European Union Directive on ‘Restriction of Hazardous Substances’ (RoHS) 2002/95/EC and imulated using the MCNPX code. Keywords: Thermal neutron radiography, MCNP, RoHS Directive

Download PDF

Export Metadata

Google Scholar

<meta name="citation_title" content="<p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p>">
<meta name="citation_author" content="Fantidis, J.">
<meta name="citation_author" content="Potolias, C.">
<meta name="citation_author" content="Vordos, N.">
<meta name="citation_author" content="Bandekas, D.">
<meta name="citation_publication_date" content="2011/02/05">
<meta name="citation_journal_title" content="Moldavian Journal of the Physical Sciences">
<meta name="citation_volume" content="10">
<meta name="citation_issue" content="1">
<meta name="citation_firstpage" content="121">
<meta name="citation_lastpage" content="130">
<meta name="citation_pdf_url" content="https://ibn.idsi.md/sites/default/files/imag_file/Optimization%20study%20of%20a%20transportable%20neutron%20radiography%20system%20based%20on%20a%20252CF%20neutron%20source.pdf">

Crossref

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-4324</doi_batch_id>
<timestamp>1597492585</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>mjps@nanotech.md</email_address>
</depositor>
<registrant>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM</registrant>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Moldavian Journal of the Physical Sciences</full_title>
<issn media_type='print'>1810648X</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2011</year>
</publication_date>
<issue>1(10)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title><p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p></title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>J.</given_name>
<surname>Fantidis</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>C.</given_name>
<surname>Potolias</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>N.</given_name>
<surname>Vordos</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>D.</given_name>
<surname>Bandekas</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2011</year>
</publication_date>
<pages>
<first_page>121</first_page>
<last_page>130</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>

CERIF

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-4324</cfResPublId>
<cfResPublDate>2011-02-05</cfResPublDate>
<cfVol>10</cfVol>
<cfIssue>1</cfIssue>
<cfStartPage>121</cfStartPage>
<cfISSN>1810-648X</cfISSN>
<cfURI>http://mjps.utm.md/archive/2011/article/4324</cfURI>
<cfTitle cfLangCode='EN' cfTrans='o'><p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p></cfTitle>
<cfKeyw cfLangCode='EN' cfTrans='o'>Thermal neutron radiography; MCNP; RoHS Directive</cfKeyw>
<cfAbstr cfLangCode='EN' cfTrans='o'>The  purpose  of  this  work  is  the  optimization  of  a  transportable  thermal  neutron 

radiography system. Neutrons are produced by a 50 mg 
252Cf source. The design was optimized 
with  respect  to parameters  related with  thermal  neutron  radiography  and  shielding. Owning  to 
the  special  collimator  design,  it was  possible  to  optimize  the  neutron  radiography  parameters, 
while the use of advanced shielding materials reduced the weight and the volume of the unit. The 
unit  was  compatible  with  the  European  Union  Directive  on  ‘Restriction  of  Hazardous 
Substances’ (RoHS) 2002/95/EC and imulated using the MCNPX code. 
Keywords: Thermal neutron radiography, MCNP, RoHS Directive </cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-35297</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-35298</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-35299</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-35300</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-35297</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-35297-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
<cfFamilyNames>Fantidis</cfFamilyNames>
<cfFirstNames>J.</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-35298</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-35298-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
<cfFamilyNames>Potolias</cfFamilyNames>
<cfFirstNames>C.</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-35299</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-35299-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
<cfFamilyNames>Vordos</cfFamilyNames>
<cfFirstNames>N.</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-35300</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-35300-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2011-02-05T24:00:00</cfStartDate>
<cfFamilyNames>Bandekas</cfFamilyNames>
<cfFirstNames>D.</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>

BibTeX

@article{ibn_4324,
author = {Fantidis, J.G. and Potolias, C. and Vordos, N. and Bandekas, D.V.},
title = {<p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p>},
journal = {Moldavian Journal of the Physical Sciences},
year = {2011},
volume = {10 (1)},
pages = {121-130},
month = {Feb},
abstract = {(EN) The  purpose  of  this  work  is  the  optimization  of  a  transportable  thermal  neutron 

radiography system. Neutrons are produced by a 50 mg 
252Cf source. The design was optimized 
with  respect  to parameters  related with  thermal  neutron  radiography  and  shielding. Owning  to 
the  special  collimator  design,  it was  possible  to  optimize  the  neutron  radiography  parameters, 
while the use of advanced shielding materials reduced the weight and the volume of the unit. The 
unit  was  compatible  with  the  European  Union  Directive  on  ‘Restriction  of  Hazardous 
Substances’ (RoHS) 2002/95/EC and imulated using the MCNPX code. 
Keywords: Thermal neutron radiography, MCNP, RoHS Directive },
url = {https://ibn.idsi.md/vizualizare_articol/4324},
keywords = {Thermal neutron radiography, MCNP, RoHS Directive}
}

DataCite

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Fantidis, J.G.</creatorName>
<affiliation>Kavala Institute of Technology, Grecia</affiliation>
</creator>
<creator>
<creatorName>Potolias, C.</creatorName>
<affiliation>Kavala Institute of Technology, Grecia</affiliation>
</creator>
<creator>
<creatorName>Vordos, N.</creatorName>
<affiliation>Kavala Institute of Technology, Grecia</affiliation>
</creator>
<creator>
<creatorName>Bandekas, D.V.</creatorName>
<affiliation>Kavala Institute of Technology, Grecia</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='en'><p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p></title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2011</publicationYear>
<relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1810-648X</relatedIdentifier>
<subjects>
<subject>Thermal neutron radiography</subject>
<subject>MCNP</subject>
<subject>RoHS Directive</subject>
</subjects>
<dates>
<date dateType='Issued'>2011-02-05</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Journal article</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'>The  purpose  of  this  work  is  the  optimization  of  a  transportable  thermal  neutron 

radiography system. Neutrons are produced by a 50 mg 
252Cf source. The design was optimized 
with  respect  to parameters  related with  thermal  neutron  radiography  and  shielding. Owning  to 
the  special  collimator  design,  it was  possible  to  optimize  the  neutron  radiography  parameters, 
while the use of advanced shielding materials reduced the weight and the volume of the unit. The 
unit  was  compatible  with  the  European  Union  Directive  on  ‘Restriction  of  Hazardous 
Substances’ (RoHS) 2002/95/EC and imulated using the MCNPX code. 
Keywords: Thermal neutron radiography, MCNP, RoHS Directive </description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>

Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'>
<dc:creator>Fantidis, J.G.</dc:creator>
<dc:creator>Potolias, C.</dc:creator>
<dc:creator>Vordos, N.</dc:creator>
<dc:creator>Bandekas, D.V.</dc:creator>
<dc:date>2011-02-05</dc:date>
<dc:description xml:lang='en'>The  purpose  of  this  work  is  the  optimization  of  a  transportable  thermal  neutron 

radiography system. Neutrons are produced by a 50 mg 
252Cf source. The design was optimized 
with  respect  to parameters  related with  thermal  neutron  radiography  and  shielding. Owning  to 
the  special  collimator  design,  it was  possible  to  optimize  the  neutron  radiography  parameters, 
while the use of advanced shielding materials reduced the weight and the volume of the unit. The 
unit  was  compatible  with  the  European  Union  Directive  on  ‘Restriction  of  Hazardous 
Substances’ (RoHS) 2002/95/EC and imulated using the MCNPX code. 
Keywords: Thermal neutron radiography, MCNP, RoHS Directive </dc:description>
<dc:source>Moldavian Journal of the Physical Sciences 10 (1) 121-130</dc:source>
<dc:subject>Thermal neutron radiography</dc:subject>
<dc:subject>MCNP</dc:subject>
<dc:subject>RoHS Directive</dc:subject>
<dc:title><p>Optimization study of a transportable neutron radiography system based on a 252CF neutron source</p></dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
</oai_dc:dc>

        

CC BY

Files

Download PDF

“ ... ”

SM ISO690:2012

FANTIDIS, J.; POTOLIAS, C.; VORDOS, N.; BANDEKAS, D.. Optimization study of a transportable neutron radiography system based on a 252CF neutron source. In: Moldavian Journal of the Physical Sciences. 2011, nr. 1(10), pp. 121-130. ISSN 1810-648X.

Views & Downloads

  • Views 479
  • Downloads 321

Archives

  • 2023 (8)
  • 2022 (11)
  • 2021 (17)
  • 2020 (8)
  • 2019 (15)
  • 2018 (26)
  • 2017 (19)
  • 2016 (33)
  • 2015 (28)
  • 2014 (28)
  • 2013 (41)
  • 2012 (44)
  • 2011 (48)
  • 2010 (48)
  • 2009 (60)
  • 2008 (67)
  • 2007 (37)
  • 2006 (52)
  • 2005 (68)

Keywords

  • Thermal neutron radiography
  • MCNP
  • RoHS Directive
Logo Logo

GHITU INSTITUTE OF ELECTRONIC
ENGINEERING AND NANOTECHNOLOGIES
INSTITUTE OF APPLIED PHYSICS
STATE UNIVERSITY OF MOLDOVA
PHYSICAL SOCIETY OF MOLDOVA

Contact Info

You can contact us in one of the following ways

  • Email: mjps@nanotech.md
  • Phone: +(373 22) 739060, +(373 22) 737092

© Copyright 2026

  • Developed by Morari Constantin