Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials

Authors:

Cherner, Iacov

Summary:

Calculation and optimization of parameters for thermoelectric sensors of infra-red radiation based on CdSb, InSb, Bi2Te3, antimony, and Bi-Sb alloys have been realized. Sensitivity, time constant, and noise equivalent power (NEP) of those sensors have been determined at different conditions. A comparative analysis of sensors based on wires or films has been made. Both advantages and disadvantages of corresponding constructions have been discussed. The obtained results have been compared with experimental data obtained in the Academy of Sciences of Moldova (ASM) and literature data. This comparison has confirmed a good quality and perspective of studied constructions.

Download PDF

Export Metadata

Google Scholar

<meta name="citation_title" content="Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials">
<meta name="citation_author" content="Cherner, Iacov">
<meta name="citation_publication_date" content="2008/10/05">
<meta name="citation_journal_title" content="Moldavian Journal of the Physical Sciences">
<meta name="citation_volume" content="7">
<meta name="citation_issue" content="4">
<meta name="citation_firstpage" content="491">
<meta name="citation_lastpage" content="498">
<meta name="citation_pdf_url" content="https://ibn.idsi.md/sites/default/files/imag_file/Numerical%20analysis%20of%20the%20non_cooled%20infrared%20sensors%20based%20on%20different%20thermoelectric%20materials.pdf">

Crossref

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-3962</doi_batch_id>
<timestamp>1597496156</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>mjps@nanotech.md</email_address>
</depositor>
<registrant>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM</registrant>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Moldavian Journal of the Physical Sciences</full_title>
<issn media_type='print'>1810648X</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2008</year>
</publication_date>
<issue>4(7)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials</title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Iacov</given_name>
<surname>Cherner</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2008</year>
</publication_date>
<pages>
<first_page>491</first_page>
<last_page>498</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>

CERIF

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-3962</cfResPublId>
<cfResPublDate>2008-10-05</cfResPublDate>
<cfVol>7</cfVol>
<cfIssue>4</cfIssue>
<cfStartPage>491</cfStartPage>
<cfISSN>1810-648X</cfISSN>
<cfURI>http://mjps.utm.md/archive/2008/article/3962</cfURI>
<cfTitle cfLangCode='EN' cfTrans='o'>Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials</cfTitle>
<cfAbstr cfLangCode='EN' cfTrans='o'>Calculation and optimization of parameters for thermoelectric sensors of infra-red 

radiation based on CdSb, InSb, Bi2Te3, antimony, and Bi-Sb alloys have been realized.  

Sensitivity, time constant, and noise equivalent power (NEP) of those sensors have been 

determined at different conditions. 
A comparative analysis of sensors based  on wires or films has been made. Both 
advantages and disadvantages of corresponding constructions have been discussed. 
The obtained results have been compared with experimental data obtained in the 
Academy of Sciences of Moldova (ASM) and literature data. This comparison has confirmed 
a good quality and perspective of studied constructions. </cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2008-10-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2008-10-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-1030</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2008-10-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-1030</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-1030-3</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2008-10-05T24:00:00</cfStartDate>
<cfFamilyNames>Kerner</cfFamilyNames>
<cfFirstNames>Iacov</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>

BibTeX

@article{ibn_3962,
author = {Cherner, I.I.},
title = {Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials},
journal = {Moldavian Journal of the Physical Sciences},
year = {2008},
volume = {7 (4)},
pages = {491-498},
month = {Oct},
abstract = {(EN) Calculation and optimization of parameters for thermoelectric sensors of infra-red 

radiation based on CdSb, InSb, Bi2Te3, antimony, and Bi-Sb alloys have been realized.  

Sensitivity, time constant, and noise equivalent power (NEP) of those sensors have been 

determined at different conditions. 
A comparative analysis of sensors based  on wires or films has been made. Both 
advantages and disadvantages of corresponding constructions have been discussed. 
The obtained results have been compared with experimental data obtained in the 
Academy of Sciences of Moldova (ASM) and literature data. This comparison has confirmed 
a good quality and perspective of studied constructions. },
url = {https://ibn.idsi.md/vizualizare_articol/3962},
}

DataCite

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Cherner, I.I.</creatorName>
<affiliation>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM, Moldova, Republica</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='en'>Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials</title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2008</publicationYear>
<relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1810-648X</relatedIdentifier>
<dates>
<date dateType='Issued'>2008-10-05</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Journal article</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'>Calculation and optimization of parameters for thermoelectric sensors of infra-red 

radiation based on CdSb, InSb, Bi2Te3, antimony, and Bi-Sb alloys have been realized.  

Sensitivity, time constant, and noise equivalent power (NEP) of those sensors have been 

determined at different conditions. 
A comparative analysis of sensors based  on wires or films has been made. Both 
advantages and disadvantages of corresponding constructions have been discussed. 
The obtained results have been compared with experimental data obtained in the 
Academy of Sciences of Moldova (ASM) and literature data. This comparison has confirmed 
a good quality and perspective of studied constructions. </description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>

Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'>
<dc:creator>Cherner, I.I.</dc:creator>
<dc:date>2008-10-05</dc:date>
<dc:description xml:lang='en'>Calculation and optimization of parameters for thermoelectric sensors of infra-red 

radiation based on CdSb, InSb, Bi2Te3, antimony, and Bi-Sb alloys have been realized.  

Sensitivity, time constant, and noise equivalent power (NEP) of those sensors have been 

determined at different conditions. 
A comparative analysis of sensors based  on wires or films has been made. Both 
advantages and disadvantages of corresponding constructions have been discussed. 
The obtained results have been compared with experimental data obtained in the 
Academy of Sciences of Moldova (ASM) and literature data. This comparison has confirmed 
a good quality and perspective of studied constructions. </dc:description>
<dc:source>Moldavian Journal of the Physical Sciences 7 (4) 491-498</dc:source>
<dc:title>Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials</dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
</oai_dc:dc>

        

CC BY

Files

Download PDF

“ ... ”

SM ISO690:2012

KERNER, Iacov. Numerical analysis of the non-cooled infrared sensors based on different thermoelectric materials. In: Moldavian Journal of the Physical Sciences. 2008, nr. 4(7), pp. 491-498. ISSN 1810-648X.

Views & Downloads

  • Views 374
  • Downloads 254

Archives

  • 2023 (8)
  • 2022 (11)
  • 2021 (17)
  • 2020 (8)
  • 2019 (15)
  • 2018 (26)
  • 2017 (19)
  • 2016 (33)
  • 2015 (28)
  • 2014 (28)
  • 2013 (41)
  • 2012 (44)
  • 2011 (48)
  • 2010 (48)
  • 2009 (60)
  • 2008 (67)
  • 2007 (37)
  • 2006 (52)
  • 2005 (68)
Logo Logo

GHITU INSTITUTE OF ELECTRONIC
ENGINEERING AND NANOTECHNOLOGIES
INSTITUTE OF APPLIED PHYSICS
STATE UNIVERSITY OF MOLDOVA
PHYSICAL SOCIETY OF MOLDOVA

Contact Info

You can contact us in one of the following ways

  • Email: mjps@nanotech.md
  • Phone: +(373 22) 739060, +(373 22) 737092

© Copyright 2026

  • Developed by Morari Constantin