Logo Logo
  • Home
    • Home
    • Editorial Board
    • Goal of the Journal
    • Submission of Papers
    • License Agreement
    • Open Access Statement
    • Guidelines for Authors
    • Peer Review Process
    • Archiving and Deposit Policies
    • Ethics of the Journal
    • Browse Journal Archive
  • Browse journal archive
  • Home
  • Archive: 2006
05 Dec 2006
  • 2006
  • V. 5
  • 3-4
  • (p.387 - 395)

Total column ozone content and aerosol optical thickness measurements: instrument performance analysis

Authors:

Aculinin, Alexandr; Smîcov, Vladimir

Summary:

Measurements of total ozone content (TOC) and aerosol optical thickness (AOT) at 1020 nm are fulfilled with microprocessor-controlled hand-held ozonometer MICROTOPS (MTOPS) #7351 at the ground-based station at the Institute of Applied Physics since July 2003. It was shown that MTOPS readings are very sensitive to errors resulting from mispointing of the instrument to the Sun. The errors in retrieved TOC values may reach up to 50% depending on Sun’s spot position in the sun targeting window of the ozonometer. MTOPS calibration characteristics are analyzed with the Langley calibration plots for clear cloudless days at the Chisinau site. Variability of evaluated calibration characteristics of instrument during period of observation consists of less than 2%. AOT values at 1020 nm retrieved from MTOPS measurements are found to be smaller than AOT from CIMEL sunphotometer operating at the Chisinau site within framework of the Aerosol Robotic Network (AERONET) under the supervision of NASA/GSFC. Discrepancy between AOT values from MTOPS and CIMEL consists, on an average, ~0.028 and this is due to the absence of temperature correction of 1020 nm channel of MTOPS. Mean ratio of daily TOC from Total Ozone Mapping Spectrometer (TOMS) aboard of Earth Probe (EP) satellite divided by TOC from MTOPS and mean ratio of daily TOC from Ozone Monitoring Instrument (OMI) aboard of Aura satellite divided by TOC from MTOPS is 0.960 and 0.990, respectively.

Download PDF

Export Metadata

Google Scholar

<meta name="citation_title" content="Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
">
<meta name="citation_author" content="Aculinin, Alexandr">
<meta name="citation_author" content="Smîcov, Vladimir">
<meta name="citation_publication_date" content="2006/12/05">
<meta name="citation_journal_title" content="Moldavian Journal of the Physical Sciences">
<meta name="citation_volume" content="5">
<meta name="citation_issue" content="3-4">
<meta name="citation_firstpage" content="387">
<meta name="citation_lastpage" content="395">
<meta name="citation_pdf_url" content="https://ibn.idsi.md/sites/default/files/imag_file/Total%20column%20ozone%20content%20and%20aerosol%20optical%20thickness.pdf">

Crossref

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-3617</doi_batch_id>
<timestamp>1597499119</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>mjps@nanotech.md</email_address>
</depositor>
<registrant>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM</registrant>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Moldavian Journal of the Physical Sciences</full_title>
<issn media_type='print'>1810648X</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2006</year>
</publication_date>
<issue>3-4(5)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
</title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Alexandr</given_name>
<surname>Aculinin</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Vladimir</given_name>
<surname>Smîcov</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2006</year>
</publication_date>
<pages>
<first_page>387</first_page>
<last_page>395</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>

CERIF

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-3617</cfResPublId>
<cfResPublDate>2006-12-05</cfResPublDate>
<cfVol>5</cfVol>
<cfIssue>3-4</cfIssue>
<cfStartPage>387</cfStartPage>
<cfISSN>1810-648X</cfISSN>
<cfURI>http://mjps.utm.md/archive/2006/article/3617</cfURI>
<cfTitle cfLangCode='RO' cfTrans='o'>Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
</cfTitle>
<cfAbstr cfLangCode='EN' cfTrans='o'>Measurements of total ozone content (TOC) and aerosol optical thickness (AOT) at 

1020 nm are fulfilled with microprocessor-controlled hand-held ozonometer MICROTOPS 
(MTOPS) #7351 at the ground-based station at the Institute of Applied Physics since July 
2003. It was shown that MTOPS readings are very sensitive to errors resulting from mispointing of the instrument to the Sun. The errors in retrieved TOC values may reach up to 50% 
depending on Sun’s spot position in the sun targeting window of the ozonometer. MTOPS 
calibration characteristics are analyzed with the Langley calibration plots for clear cloudless 
days at the Chisinau site. Variability of evaluated calibration characteristics of instrument during period of observation consists of less than 2%. AOT values at 1020 nm retrieved from 
MTOPS measurements are found to be smaller than AOT from CIMEL sunphotometer operating at the Chisinau site within framework of the Aerosol Robotic Network (AERONET) 
under the supervision of NASA/GSFC. Discrepancy between AOT values from MTOPS and 
CIMEL consists, on an average, ~0.028 and this is due to the absence of temperature correction of 1020 nm channel of MTOPS. Mean ratio of daily TOC from Total Ozone Mapping 
Spectrometer (TOMS) aboard of Earth Probe (EP) satellite divided by TOC from MTOPS and 
mean ratio of daily TOC from Ozone Monitoring Instrument (OMI) aboard of Aura satellite 
divided by TOC from MTOPS is 0.960 and 0.990, respectively. 
</cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-682</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-13202</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-682</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-682-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
<cfFamilyNames>Aculinin</cfFamilyNames>
<cfFirstNames>Alexandr</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-13202</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-13202-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2006-12-05T24:00:00</cfStartDate>
<cfFamilyNames>Smîcov</cfFamilyNames>
<cfFirstNames>Vladimir</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>

BibTeX

@article{ibn_3617,
author = {Aculinin, A.A. and Smîcov, V.P.},
title = {Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
},
journal = {Moldavian Journal of the Physical Sciences},
year = {2006},
volume = {5 (3-4)},
pages = {387-395},
month = {Dec},
abstract = {(EN) Measurements of total ozone content (TOC) and aerosol optical thickness (AOT) at 

1020 nm are fulfilled with microprocessor-controlled hand-held ozonometer MICROTOPS 
(MTOPS) #7351 at the ground-based station at the Institute of Applied Physics since July 
2003. It was shown that MTOPS readings are very sensitive to errors resulting from mispointing of the instrument to the Sun. The errors in retrieved TOC values may reach up to 50% 
depending on Sun’s spot position in the sun targeting window of the ozonometer. MTOPS 
calibration characteristics are analyzed with the Langley calibration plots for clear cloudless 
days at the Chisinau site. Variability of evaluated calibration characteristics of instrument during period of observation consists of less than 2%. AOT values at 1020 nm retrieved from 
MTOPS measurements are found to be smaller than AOT from CIMEL sunphotometer operating at the Chisinau site within framework of the Aerosol Robotic Network (AERONET) 
under the supervision of NASA/GSFC. Discrepancy between AOT values from MTOPS and 
CIMEL consists, on an average, ~0.028 and this is due to the absence of temperature correction of 1020 nm channel of MTOPS. Mean ratio of daily TOC from Total Ozone Mapping 
Spectrometer (TOMS) aboard of Earth Probe (EP) satellite divided by TOC from MTOPS and 
mean ratio of daily TOC from Ozone Monitoring Instrument (OMI) aboard of Aura satellite 
divided by TOC from MTOPS is 0.960 and 0.990, respectively. 
},
url = {https://ibn.idsi.md/vizualizare_articol/3617},
}

DataCite

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Aculinin, A.A.</creatorName>
<affiliation>Institutul de Fizică Aplicată al AŞM, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Smîcov, V.P.</creatorName>
<affiliation>Institutul de Fizică Aplicată al AŞM, Moldova, Republica</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='ro'>Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
</title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2006</publicationYear>
<relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1810-648X</relatedIdentifier>
<dates>
<date dateType='Issued'>2006-12-05</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Journal article</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'>Measurements of total ozone content (TOC) and aerosol optical thickness (AOT) at 

1020 nm are fulfilled with microprocessor-controlled hand-held ozonometer MICROTOPS 
(MTOPS) #7351 at the ground-based station at the Institute of Applied Physics since July 
2003. It was shown that MTOPS readings are very sensitive to errors resulting from mispointing of the instrument to the Sun. The errors in retrieved TOC values may reach up to 50% 
depending on Sun’s spot position in the sun targeting window of the ozonometer. MTOPS 
calibration characteristics are analyzed with the Langley calibration plots for clear cloudless 
days at the Chisinau site. Variability of evaluated calibration characteristics of instrument during period of observation consists of less than 2%. AOT values at 1020 nm retrieved from 
MTOPS measurements are found to be smaller than AOT from CIMEL sunphotometer operating at the Chisinau site within framework of the Aerosol Robotic Network (AERONET) 
under the supervision of NASA/GSFC. Discrepancy between AOT values from MTOPS and 
CIMEL consists, on an average, ~0.028 and this is due to the absence of temperature correction of 1020 nm channel of MTOPS. Mean ratio of daily TOC from Total Ozone Mapping 
Spectrometer (TOMS) aboard of Earth Probe (EP) satellite divided by TOC from MTOPS and 
mean ratio of daily TOC from Ozone Monitoring Instrument (OMI) aboard of Aura satellite 
divided by TOC from MTOPS is 0.960 and 0.990, respectively. 
</description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>

Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'>
<dc:creator>Aculinin, A.A.</dc:creator>
<dc:creator>Smîcov, V.P.</dc:creator>
<dc:date>2006-12-05</dc:date>
<dc:description xml:lang='en'>Measurements of total ozone content (TOC) and aerosol optical thickness (AOT) at 

1020 nm are fulfilled with microprocessor-controlled hand-held ozonometer MICROTOPS 
(MTOPS) #7351 at the ground-based station at the Institute of Applied Physics since July 
2003. It was shown that MTOPS readings are very sensitive to errors resulting from mispointing of the instrument to the Sun. The errors in retrieved TOC values may reach up to 50% 
depending on Sun’s spot position in the sun targeting window of the ozonometer. MTOPS 
calibration characteristics are analyzed with the Langley calibration plots for clear cloudless 
days at the Chisinau site. Variability of evaluated calibration characteristics of instrument during period of observation consists of less than 2%. AOT values at 1020 nm retrieved from 
MTOPS measurements are found to be smaller than AOT from CIMEL sunphotometer operating at the Chisinau site within framework of the Aerosol Robotic Network (AERONET) 
under the supervision of NASA/GSFC. Discrepancy between AOT values from MTOPS and 
CIMEL consists, on an average, ~0.028 and this is due to the absence of temperature correction of 1020 nm channel of MTOPS. Mean ratio of daily TOC from Total Ozone Mapping 
Spectrometer (TOMS) aboard of Earth Probe (EP) satellite divided by TOC from MTOPS and 
mean ratio of daily TOC from Ozone Monitoring Instrument (OMI) aboard of Aura satellite 
divided by TOC from MTOPS is 0.960 and 0.990, respectively. 
</dc:description>
<dc:source>Moldavian Journal of the Physical Sciences 5 (3-4) 387-395</dc:source>
<dc:title>Total column ozone content and aerosol optical thickness measurements: instrument performance analysis 
</dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
</oai_dc:dc>

        

CC BY

Files

Download PDF

“ ... ”

SM ISO690:2012

ACULININ, Alexandr; SMÎCOV, Vladimir. Total column ozone content and aerosol optical thickness measurements: instrument performance analysis . In: Moldavian Journal of the Physical Sciences. 2006, nr. 3-4(5), pp. 387-395. ISSN 1810-648X.

Views & Downloads

  • Views 434
  • Downloads 298

Archives

  • 2023 (8)
  • 2022 (11)
  • 2021 (17)
  • 2020 (8)
  • 2019 (15)
  • 2018 (26)
  • 2017 (19)
  • 2016 (33)
  • 2015 (28)
  • 2014 (28)
  • 2013 (41)
  • 2012 (44)
  • 2011 (48)
  • 2010 (48)
  • 2009 (60)
  • 2008 (67)
  • 2007 (37)
  • 2006 (52)
  • 2005 (68)
Logo Logo

GHITU INSTITUTE OF ELECTRONIC
ENGINEERING AND NANOTECHNOLOGIES
INSTITUTE OF APPLIED PHYSICS
STATE UNIVERSITY OF MOLDOVA
PHYSICAL SOCIETY OF MOLDOVA

Contact Info

You can contact us in one of the following ways

  • Email: mjps@nanotech.md
  • Phone: +(373 22) 739060, +(373 22) 737092

© Copyright 2026

  • Developed by Morari Constantin