Logo Logo
  • Home
    • Home
    • Editorial Board
    • Goal of the Journal
    • Submission of Papers
    • License Agreement
    • Open Access Statement
    • Guidelines for Authors
    • Peer Review Process
    • Archiving and Deposit Policies
    • Ethics of the Journal
    • Browse Journal Archive
  • Browse journal archive
  • Home
  • Archive: 2006
05 Apr 2006
  • 2006
  • V. 5
  • 2
  • (p.240 - 248)

Variability of total column ozone content measured at Chisinau site, Republic of Moldov

Authors:

Aculinin, Alexandr

Summary:

Results of the total column ozone measurements at the ground-based solar radiation monitoring station in Chisinau, Moldova are presented. Column ozone content was derived from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand- held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals distinctive seasonal variation at the Chisinau site with maximum and minimum values in spring and fall, respectively. Climatic mean value of total column ozone content derived from TOMS data at the Chisinau site amounts to 334.7 DU. 1. Introduction

Download PDF

Export Metadata

Google Scholar

<meta name="citation_title" content="Variability of total column ozone content measured at Chisinau site, Republic of Moldov ">
<meta name="citation_author" content="Aculinin, Alexandr">
<meta name="citation_publication_date" content="2006/04/05">
<meta name="citation_journal_title" content="Moldavian Journal of the Physical Sciences">
<meta name="citation_volume" content="5">
<meta name="citation_issue" content="2">
<meta name="citation_firstpage" content="240">
<meta name="citation_lastpage" content="248">
<meta name="citation_pdf_url" content="https://ibn.idsi.md/sites/default/files/imag_file/Variability%20of%20total%20column%20ozone%20content%20measured.pdf">

Crossref

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-3495</doi_batch_id>
<timestamp>1597499492</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>mjps@nanotech.md</email_address>
</depositor>
<registrant>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM</registrant>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Moldavian Journal of the Physical Sciences</full_title>
<issn media_type='print'>1810648X</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2006</year>
</publication_date>
<issue>2(5)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Variability of total column ozone content measured at Chisinau site, Republic of Moldov </title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Alexandr</given_name>
<surname>Aculinin</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2006</year>
</publication_date>
<pages>
<first_page>240</first_page>
<last_page>248</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>

CERIF

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-3495</cfResPublId>
<cfResPublDate>2006-04-05</cfResPublDate>
<cfVol>5</cfVol>
<cfIssue>2</cfIssue>
<cfStartPage>240</cfStartPage>
<cfISSN>1810-648X</cfISSN>
<cfURI>http://mjps.utm.md/archive/2006/article/3495</cfURI>
<cfTitle cfLangCode='RO' cfTrans='o'>Variability of total column ozone content measured at Chisinau site, Republic of Moldov </cfTitle>
<cfAbstr cfLangCode='EN' cfTrans='o'>Results of the total column ozone measurements at the ground-based solar radiation 

monitoring station in Chisinau, Moldova are presented. Column ozone content was derived 
from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 
312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand-
held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone 
content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe 
equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals 
distinctive seasonal variation at the Chisinau site with maximum and minimum values in 
spring and fall, respectively. Climatic mean value of total column ozone content derived from 
TOMS data at the Chisinau site amounts to 334.7 DU. 
1. Introduction </cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2006-04-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2006-04-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-682</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2006-04-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-682</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-682-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2006-04-05T24:00:00</cfStartDate>
<cfFamilyNames>Aculinin</cfFamilyNames>
<cfFirstNames>Alexandr</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>

BibTeX

@article{ibn_3495,
author = {Aculinin, A.A.},
title = {Variability of total column ozone content measured at Chisinau site, Republic of Moldov },
journal = {Moldavian Journal of the Physical Sciences},
year = {2006},
volume = {5 (2)},
pages = {240-248},
month = {Apr},
abstract = {(EN) Results of the total column ozone measurements at the ground-based solar radiation 

monitoring station in Chisinau, Moldova are presented. Column ozone content was derived 
from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 
312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand-
held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone 
content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe 
equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals 
distinctive seasonal variation at the Chisinau site with maximum and minimum values in 
spring and fall, respectively. Climatic mean value of total column ozone content derived from 
TOMS data at the Chisinau site amounts to 334.7 DU. 
1. Introduction },
url = {https://ibn.idsi.md/vizualizare_articol/3495},
}

DataCite

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Aculinin, A.A.</creatorName>
<affiliation>Institutul de Fizică Aplicată al AŞM, Moldova, Republica</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='ro'>Variability of total column ozone content measured at Chisinau site, Republic of Moldov </title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2006</publicationYear>
<relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1810-648X</relatedIdentifier>
<dates>
<date dateType='Issued'>2006-04-05</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Journal article</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'>Results of the total column ozone measurements at the ground-based solar radiation 

monitoring station in Chisinau, Moldova are presented. Column ozone content was derived 
from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 
312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand-
held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone 
content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe 
equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals 
distinctive seasonal variation at the Chisinau site with maximum and minimum values in 
spring and fall, respectively. Climatic mean value of total column ozone content derived from 
TOMS data at the Chisinau site amounts to 334.7 DU. 
1. Introduction </description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>

Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'>
<dc:creator>Aculinin, A.A.</dc:creator>
<dc:date>2006-04-05</dc:date>
<dc:description xml:lang='en'>Results of the total column ozone measurements at the ground-based solar radiation 

monitoring station in Chisinau, Moldova are presented. Column ozone content was derived 
from the ratios of direct solar ultraviolet radiances measured at 3 discrete wavelengths 305-, 
312-, 320-nm within UV-B range. Ozone measurements are regularly carried out with hand-
held MICROTOPS II Ozonometer, Solar Light Co. Monthly averages of total column ozone 
content measured with MICROTOPS II ozonometer at the Chisinau site are in close agreement with those retrieved from the multi-year (1957-2005) measurements carried out at number of ground stations and at the satellite platforms Nimbus -7, Meteor-3, and Earth Probe 
equipped with the Total Ozone Mapping Spectrometer (TOMS). Total ozone content reveals 
distinctive seasonal variation at the Chisinau site with maximum and minimum values in 
spring and fall, respectively. Climatic mean value of total column ozone content derived from 
TOMS data at the Chisinau site amounts to 334.7 DU. 
1. Introduction </dc:description>
<dc:source>Moldavian Journal of the Physical Sciences 5 (2) 240-248</dc:source>
<dc:title>Variability of total column ozone content measured at Chisinau site, Republic of Moldov </dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
</oai_dc:dc>

        

CC BY

Files

Download PDF

“ ... ”

SM ISO690:2012

ACULININ, Alexandr. Variability of total column ozone content measured at Chisinau site, Republic of Moldov . In: Moldavian Journal of the Physical Sciences. 2006, nr. 2(5), pp. 240-248. ISSN 1810-648X.

Views & Downloads

  • Views 552
  • Downloads 347

Archives

  • 2023 (8)
  • 2022 (11)
  • 2021 (17)
  • 2020 (8)
  • 2019 (15)
  • 2018 (26)
  • 2017 (19)
  • 2016 (33)
  • 2015 (28)
  • 2014 (28)
  • 2013 (41)
  • 2012 (44)
  • 2011 (48)
  • 2010 (48)
  • 2009 (60)
  • 2008 (67)
  • 2007 (37)
  • 2006 (52)
  • 2005 (68)
Logo Logo

GHITU INSTITUTE OF ELECTRONIC
ENGINEERING AND NANOTECHNOLOGIES
INSTITUTE OF APPLIED PHYSICS
STATE UNIVERSITY OF MOLDOVA
PHYSICAL SOCIETY OF MOLDOVA

Contact Info

You can contact us in one of the following ways

  • Email: mjps@nanotech.md
  • Phone: +(373 22) 739060, +(373 22) 737092

© Copyright 2026

  • Developed by Morari Constantin