Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method

Authors:

Dementiev, Igor; Maximov, Eugen; Pocatilov, Evghenii; Taracanova, Larisa

Summary:

To record Roentgen image on sillenite-type crystals while charging in a corona discharge field, a device has been performed. The resolution not less than 10 pairs of lines per mm, the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the exposure length of 0.6 s were obtained using Bi12GeO20 crystal. The device survives more than 104 of writing-erase cycles. From the sensitivity point of view, the considered registration is just as good as X-Ray films used for radiography and dosimetry.

Download PDF

Export Metadata

Google Scholar

<meta name="citation_title" content="Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method">
<meta name="citation_author" content="Dementiev, Igor">
<meta name="citation_author" content="Maximov, Eugen">
<meta name="citation_author" content="Pocatilov, Evghenii">
<meta name="citation_author" content="Taracanova, Larisa">
<meta name="citation_publication_date" content="2005/01/05">
<meta name="citation_journal_title" content="Moldavian Journal of the Physical Sciences">
<meta name="citation_volume" content="4">
<meta name="citation_issue" content="1">
<meta name="citation_firstpage" content="64">
<meta name="citation_lastpage" content="68">
<meta name="citation_pdf_url" content="https://ibn.idsi.md/sites/default/files/imag_file/Roentgen%20image%20recording%20on%20sillenite_type%20electrooptical%20crystals%20by%20electrophotographic%20method.pdf">

Crossref

<?xml version='1.0' encoding='utf-8'?>
<doi_batch version='4.3.7' xmlns='http://www.crossref.org/schema/4.3.7' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.crossref.org/schema/4.3.7 http://www.crossref.org/schema/deposit/crossref4.3.7.xsd'>
<head>
<doi_batch_id>ibn-3057</doi_batch_id>
<timestamp>1597501676</timestamp>
<depositor>
<depositor_name>Information Society Development Instiute, Republic of Moldova</depositor_name>
<email_address>mjps@nanotech.md</email_address>
</depositor>
<registrant>Institutul de Inginerie Electronică şi Nanotehnologii "D. Ghiţu" al AŞM</registrant>
</head>
<body>
<journal>
<journal_metadata>
<full_title>Moldavian Journal of the Physical Sciences</full_title>
<issn media_type='print'>1810648X</issn>
</journal_metadata>
<journal_issue>
<publication_date media_type='print'>
<year>2005</year>
</publication_date>
<issue>1(4)</issue>
</journal_issue>
<journal_article publication_type='full_text'><titles>
<title>Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method</title>
</titles>
<contributors>
<person_name sequence='first' contributor_role='author'>
<given_name>Igor</given_name>
<surname>Dementiev</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Eugen</given_name>
<surname>Maximov</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Evghenii</given_name>
<surname>Pocatilov</surname>
</person_name>
<person_name sequence='additional' contributor_role='author'>
<given_name>Larisa</given_name>
<surname>Taracanova</surname>
</person_name>
</contributors>
<publication_date media_type='print'>
<year>2005</year>
</publication_date>
<pages>
<first_page>64</first_page>
<last_page>68</last_page>
</pages>
</journal_article>
</journal>
</body>
</doi_batch>

CERIF

<?xml version='1.0' encoding='utf-8'?>
<CERIF xmlns='urn:xmlns:org:eurocris:cerif-1.5-1' xsi:schemaLocation='urn:xmlns:org:eurocris:cerif-1.5-1 http://www.eurocris.org/Uploads/Web%20pages/CERIF-1.5/CERIF_1.5_1.xsd' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' release='1.5' date='2012-10-07' sourceDatabase='Output Profile'>
<cfResPubl>
<cfResPublId>ibn-ResPubl-3057</cfResPublId>
<cfResPublDate>2005-01-05</cfResPublDate>
<cfVol>4</cfVol>
<cfIssue>1</cfIssue>
<cfStartPage>64</cfStartPage>
<cfISSN>1810-648X</cfISSN>
<cfURI>http://mjps.utm.md/archive/2005/article/3057</cfURI>
<cfTitle cfLangCode='RO' cfTrans='o'>Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method</cfTitle>
<cfAbstr cfLangCode='EN' cfTrans='o'>To  record  Roentgen  image  on  sillenite-type  crystals  while  charging  in  a  corona 

discharge field, a device has been performed. The resolution not less than 10 pairs of lines per 
mm,  the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the 
exposure  length  of  0.6  s were  obtained  using Bi12GeO20  crystal. The  device  survives more than  104 
of  writing-erase  cycles.  From  the  sensitivity  point  of  view,  the  considered 
registration is just as good as X-Ray films used for radiography and dosimetry.    </cfAbstr>
<cfResPubl_Class>
<cfClassId>eda2d9e9-34c5-11e1-b86c-0800200c9a66</cfClassId>
<cfClassSchemeId>759af938-34ae-11e1-b86c-0800200c9a66</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfResPubl_Class>
<cfClassId>e601872f-4b7e-4d88-929f-7df027b226c9</cfClassId>
<cfClassSchemeId>40e90e2f-446d-460a-98e5-5dce57550c48</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfResPubl_Class>
<cfPers_ResPubl>
<cfPersId>ibn-person-1003</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-13819</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-371</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
<cfPers_ResPubl>
<cfPersId>ibn-person-13338</cfPersId>
<cfClassId>49815870-1cfe-11e1-8bc2-0800200c9a66</cfClassId>
<cfClassSchemeId>b7135ad0-1d00-11e1-8bc2-0800200c9a66</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
</cfPers_ResPubl>
</cfResPubl>
<cfPers>
<cfPersId>ibn-Pers-1003</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-1003-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
<cfFamilyNames>Дементьев</cfFamilyNames>
<cfFirstNames>Игорь</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-13819</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-13819-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
<cfFamilyNames>Maximov</cfFamilyNames>
<cfFirstNames>Eugen</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-371</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-371-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
<cfFamilyNames>Pokatilov</cfFamilyNames>
<cfFirstNames>Evghenii</cfFirstNames>
<cfFamilyNames>Покатилов</cfFamilyNames>
<cfFirstNames>Евгений</cfFirstNames>
</cfPersName_Pers>
</cfPers>
<cfPers>
<cfPersId>ibn-Pers-13338</cfPersId>
<cfPersName_Pers>
<cfPersNameId>ibn-PersName-13338-2</cfPersNameId>
<cfClassId>55f90543-d631-42eb-8d47-d8d9266cbb26</cfClassId>
<cfClassSchemeId>7375609d-cfa6-45ce-a803-75de69abe21f</cfClassSchemeId>
<cfStartDate>2005-01-05T24:00:00</cfStartDate>
<cfFamilyNames>Taracanova</cfFamilyNames>
<cfFirstNames>Larisa</cfFirstNames>
</cfPersName_Pers>
</cfPers>
</CERIF>

BibTeX

@article{ibn_3057,
author = {Dementiev, I.V. and Maximov, E. and Pocatilov, E.P. and Taracanova, L.},
title = {Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method},
journal = {Moldavian Journal of the Physical Sciences},
year = {2005},
volume = {4 (1)},
pages = {64-68},
month = {Jan},
abstract = {(EN) To  record  Roentgen  image  on  sillenite-type  crystals  while  charging  in  a  corona 

discharge field, a device has been performed. The resolution not less than 10 pairs of lines per 
mm,  the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the 
exposure  length  of  0.6  s were  obtained  using Bi12GeO20  crystal. The  device  survives more than  104 
of  writing-erase  cycles.  From  the  sensitivity  point  of  view,  the  considered 
registration is just as good as X-Ray films used for radiography and dosimetry.    },
url = {https://ibn.idsi.md/vizualizare_articol/3057},
}

DataCite

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xmlns='http://datacite.org/schema/kernel-3' xsi:schemaLocation='http://datacite.org/schema/kernel-3 http://schema.datacite.org/meta/kernel-3/metadata.xsd'>
<creators>
<creator>
<creatorName>Dementiev, I.V.</creatorName>
<affiliation>Universitatea de Stat din Moldova, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Maximov, E.</creatorName>
<affiliation>Universitatea de Stat din Moldova, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Pocatilov, E.P.</creatorName>
<affiliation>Universitatea de Stat din Moldova, Moldova, Republica</affiliation>
</creator>
<creator>
<creatorName>Taracanova, L.</creatorName>
<affiliation>Universitatea de Stat din Moldova, Moldova, Republica</affiliation>
</creator>
</creators>
<titles>
<title xml:lang='ro'>Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method</title>
</titles>
<publisher>Instrumentul Bibliometric National</publisher>
<publicationYear>2005</publicationYear>
<relatedIdentifier relatedIdentifierType='ISSN' relationType='IsPartOf'>1810-648X</relatedIdentifier>
<dates>
<date dateType='Issued'>2005-01-05</date>
</dates>
<resourceType resourceTypeGeneral='Text'>Journal article</resourceType>
<descriptions>
<description xml:lang='en' descriptionType='Abstract'>To  record  Roentgen  image  on  sillenite-type  crystals  while  charging  in  a  corona 

discharge field, a device has been performed. The resolution not less than 10 pairs of lines per 
mm,  the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the 
exposure  length  of  0.6  s were  obtained  using Bi12GeO20  crystal. The  device  survives more than  104 
of  writing-erase  cycles.  From  the  sensitivity  point  of  view,  the  considered 
registration is just as good as X-Ray films used for radiography and dosimetry.    </description>
</descriptions>
<formats>
<format>application/pdf</format>
</formats>
</resource>

Dublin Core

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc='http://purl.org/dc/elements/1.1/' xmlns:oai_dc='http://www.openarchives.org/OAI/2.0/oai_dc/' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance' xsi:schemaLocation='http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd'>
<dc:creator>Dementiev, I.V.</dc:creator>
<dc:creator>Maximov, E.</dc:creator>
<dc:creator>Pocatilov, E.P.</dc:creator>
<dc:creator>Taracanova, L.</dc:creator>
<dc:date>2005-01-05</dc:date>
<dc:description xml:lang='en'>To  record  Roentgen  image  on  sillenite-type  crystals  while  charging  in  a  corona 

discharge field, a device has been performed. The resolution not less than 10 pairs of lines per 
mm,  the sensitivity of 25 reciprocal Roentgens, the contrast coefficient not less than 2 at the 
exposure  length  of  0.6  s were  obtained  using Bi12GeO20  crystal. The  device  survives more than  104 
of  writing-erase  cycles.  From  the  sensitivity  point  of  view,  the  considered 
registration is just as good as X-Ray films used for radiography and dosimetry.    </dc:description>
<dc:source>Moldavian Journal of the Physical Sciences 4 (1) 64-68</dc:source>
<dc:title>Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method</dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
</oai_dc:dc>

        

CC BY

Files

Download PDF

“ ... ”

SM ISO690:2012

DEMENTIEV, Igor; MAXIMOV, Eugen; POCATILOV, Evghenii; TARACANOVA, Larisa. Roentgen image recording on sillenite-type electrooptical crystals by electrophotographic method. In: Moldavian Journal of the Physical Sciences. 2005, nr. 1(4), pp. 64-68. ISSN 1810-648X.

Views & Downloads

  • Views 436
  • Downloads 345

Archives

  • 2023 (8)
  • 2022 (11)
  • 2021 (17)
  • 2020 (8)
  • 2019 (15)
  • 2018 (26)
  • 2017 (19)
  • 2016 (33)
  • 2015 (28)
  • 2014 (28)
  • 2013 (41)
  • 2012 (44)
  • 2011 (48)
  • 2010 (48)
  • 2009 (60)
  • 2008 (67)
  • 2007 (37)
  • 2006 (52)
  • 2005 (68)
Logo Logo

GHITU INSTITUTE OF ELECTRONIC
ENGINEERING AND NANOTECHNOLOGIES
INSTITUTE OF APPLIED PHYSICS
STATE UNIVERSITY OF MOLDOVA
PHYSICAL SOCIETY OF MOLDOVA

Contact Info

You can contact us in one of the following ways

  • Email: mjps@nanotech.md
  • Phone: +(373 22) 739060, +(373 22) 737092

© Copyright 2026

  • Developed by Morari Constantin